Headlight Tester Calibrator (MQB-1B)
AgencyPWM-modulated standard light source with manual horizontal/vertical angle adjustment; 5,000-65,000 cd, intensity error ±4%, angle error ±5'; compliant with JJG 967 and JJG 745
Product Details
Agent Products | Motor Vehicle Headlight (Light) Detection Equipment
Headlight Detector Calibrator (Light Calibration Tool MQB-1B)
PWM modulates constant light intensity standard light source, manually adjusts horizontal/vertical angle; luminous intensity 5000 ~ 65000cd, luminous intensity error ± 4%, angle error ± 5 ′; conforms to JJG 967, JJG 745 calibration regulations
MQB-1B headlight detector calibrator: standard light source box and tripod| Control the luminous intensity of the light source using PWM modulation technology Ensure the stability of the light source (luminous intensity stability ± 1.5%/h). | Manually adjust the level The vertical angle knob controls the high beam or laser beam of the optical axis angle, which can be used to test the luminous intensity of the headlight detector, the optical axis offset angle, and the angle of the low-light light/dark cutoff line. | Calibrator equipped with standard light source Equipped with horizontal and vertical precision rotation mechanism, as well as horizontal adjustment mechanism and alignment mechanism, it is convenient for on-site alignment and adjustment. |
产品概述
The MQB-1B headlight detector calibrator uses PWM modulation technology to control the luminous intensity of the light source to ensure the stability of the light source; the horizontal and vertical angle knobs are used to manually adjust the far beam or laser beam of the optical axis angle to achieve the detection of the luminous intensity of the headlight detector, the optical axis offset angle and the angle of the low-light dark cut-off line.
The calibrator complies with JJG 967 "Verification Procedure for Motor Vehicle Headlight Detector Calibrator" and JJG 745 "Verification Procedure for Motor Vehicle Headlight Detector"; applicable to the ex-factory inspection of motor vehicle headlight detector, and the inspection after maintenance of the detector by the motor vehicle headlight detector maintenance department.
The MQB-1B calibrator is equipped with a standard light source, a device with a horizontal and vertical precision rotation mechanism, and consists of a standard light source, a laser, a DC regulated power supply and a voltmeter, a horizontal and vertical angle rotation mechanism, a horizontal adjustment mechanism, and a correction mechanism.
Core Strengths
■The luminous intensity of the light source is controlled by PWM modulation technology to ensure the stability of the light source (luminous intensity stability ± 1.5%/h). ■Manually adjust the horizontal and vertical angle knobs to control the high beam or laser beam of the optical axis angle, which can be used to test the luminous intensity, optical axis offset angle and the angle of the low-light light and dark cutoff line of the headlight detector. ■The calibrator is equipped with a standard light source, with horizontal and vertical precision rotation mechanisms, as well as a horizontal adjustment mechanism and alignment mechanism to facilitate on-site alignment and adjustment. ■The luminous intensity error is ± 4%, the repeatability error is 1%, the angle error is ± 5 ′, and the idle travel error is ± 3 ′, which meets the verification requirements of the headlamp detector. | ■The luminous intensity ranges from 5000 to 65000cd, the light deflection angle is 3° up to 3° 30 ′ down, and the left 3° to right 3°, covering the verification interval of common headlight detectors. ■In accordance with JJG 967 and JJG 745 calibration procedures, it can be used for the inspection of the detector after factory inspection and maintenance. ■The box and the stand are separated and portable: the box is 380mm × 355mm × 415mm, the stand is 280mm × 280mm × 800mm, the total weight is about 16kg, suitable for on-site and laboratory use. |
Structure and Details
Calibrator structure and components labeling: standard light source, laser, voltmeter, angle and level adjustment mechanism, etc. |
(II) Main technical parameters
| Model | Model MQB-1B Motor Vehicle Headlight Detector Calibrator (Far and Near Light Calibrator) |
| Calibration Items | Far light luminous intensity and offset of far and low light optical axes |
| Luminous Intensity Range | (5000-65,000) cd |
| Light Deflection Angle | 3° up to 3° 30 ′ down; 3° left to 3° right |
| Luminous intensity error | ±4% |
| Luminous intensity repeatability error | 1% |
| Luminous intensity stability | ± 1.5%/h |
| Angle error | 5 |
| Idle travel error | 3 |
| Power Supply | AC (220V ± 22V); (50 ± 1) Hz |
| Dimensions (W × H × D) | Box: 380mm × 355mm × 415mm; Stand: 280mm × 280mm × 800mm |
| Weight | Approx. 16 kg |
| component part | Standard light source, laser, DC regulated power supply and voltmeter, horizontal and vertical angle rotation mechanism, horizontal adjustment mechanism, alignment mechanism |
| According to the procedure | JJG 967 "Verification Procedure for Motor Vehicle Headlight Detector Calibrator", JJG 745 "Verification Procedure for Motor Vehicle Headlight Detector" |
| Applicable Scenario | Factory inspection of motor vehicle headlamp detector; inspection after maintenance by detector maintenance department |
Contact us
Beijing Taiyuanxiang Technology Co., Ltd. Phone: 010-89780650 Mobile: 18611929790 (Li Yongpo)Email: liyongpo@taiyuanxiang.cn
Address: Room 3027, Building 1, Hongfu No. 10, Beiqijia Town, Changping District, Beijing
Service content: complete machine sales, installation and commissioning, calibration and accuracy check, operation training, after-sales maintenance and spare parts supply Note: The parameters and pictures on this page are compiled from the technical data of the product and are only used for product introduction; the product configuration and parameters are updated without notice, and the specifics are subject to the physical and contractual agreements.
Related Products
View All
Wheel Alignment System CEMB ARGOS (Italy)
Fully fixture-free 3D structured-light scanning wheel aligner: 4 columns / 8 cameras, toe & camber in 5 s, full test in 70 s, accuracy ±0.02°
Learn More
Headlight Tester SAM2000 (LITE Belgium, Rail Type)
CCD digital camera with CANBUS module, fully automatic aiming and centring; 0-125,000 cd, position offset ±100 cm/10 m, 35 s cycle; pass windows generated per GB7258-2017
Learn More
Wheel Aligner JohnBean i-Aligner Platinum³
JohnBean i-Aligner™ imaging alignment system for OEM end-of-line wheel alignment inspection
Learn More
Headlight Tester MQD-6B (Zheda Mingquan)
High-speed DSP (DSP6000) with twin CCD, fully automatic aiming and measurement; about 40 s for single lamp and 25 s for two lamps; supplied with alarm lamp, frame grabber and PC software
Learn MoreMore in This Category
View All- Wheel Alignment System CEMB ARGOS (Italy)
- Headlight Tester SAM2000 (LITE Belgium, Rail Type)
- Wheel Aligner JohnBean i-Aligner Platinum³
- Headlight Tester MQD-6B (Zheda Mingquan)
- Truck Wheel Alignment Hunter DSP760TCX (USA)
- Headlight Tester MQD-3B (Zheda Mingquan)
- TruckCam Camera Wheel Alignment System (Sweden)
- HAWEKA AXIS4000 Mobile Truck Wheel Alignment System
- Drive-through Wheel Alignment VECTOR-7202MAB (Russia)
- Non-contact Wheel Alignment Vector TV8 (Auto Track Width)
Calibrator structure and components labeling: standard light source, laser, voltmeter, angle and level adjustment mechanism, etc.